Skip to content
Certified ManufacturersFor manufacturers
← Testing laboratories

Servicio Integral A LA Agroindustria S.A. De C.V.

Queretaro, Queretaro, MX

Accreditation body named by FDA
Mexican Accreditation Entity, a.c.
Source checked
External-client availability
Unknown — confirm directly
Active scope records
8

These records come from FDA’s LAAF laboratory and scope exports. LAAF covers specified food-testing circumstances. Accreditation applies to the listed methods and matrices; it does not establish every service a lab offers or acceptance by Amazon.

External-client availability is unknown. Some laboratories may serve their own company. Confirm that the location accepts your samples and that your product, analytes and required methods fall within its current scope.

Check the FDA LAAF registry · What the programme covers

Accreditation scopes and status

Read each analyte together with its matrix and method. A food matrix does not automatically include supplements. Earlier records retained from a prior import show their own check date.

Taint · A-0434-037/13

Approved Scope

Specific analytes
2,4.6-Trichloroanisole
Matrices
Wine
Method / technology
PR-5-90 Determination of 2,4,6-Trichloroanisole (based on Ultra-trace analysis of 2,4.6-Tricholoranisole in White Wine using Automated SPME and the Varian 240-MS Ion Trap Mass Spectrometer; Application Note SI-02373) · GC-MS
Effective date / source checked
2023-12-07 / 2026-10-16

No directory test category assigned.

Verify certificate and current scope in the FDA registry

Pesticides · A-0434-037/13

Approved Scope

Specific analytes
Pesticides, multi-residue, see scope certificate for list
Matrices
Fresh and processed foods
Method / technology
PR-5-14 Determination of Pesticide Residues in Fresh and Processed Foods by Mass Gas Chromatography (based on AOAC 2007.01) · GC-MS
Effective date / source checked
2023-12-07 / 2026-10-16

Pesticide testing

Verify certificate and current scope in the FDA registry

Pesticides · A-0434-037/13

Approved Scope

Specific analytes
Pesticides (polar): Fosetyl Aluminum, Phosphonic Acid, Ethephon, Chlorate and Perchlorate
Matrices
Food of plant origin
Method / technology
Determination of polar pesticides by methanol extraction and identification by liquid chromatography coupled to mass/mass detector · LC-MS/MS
Effective date / source checked
2023-12-07 / 2026-10-16

Pesticide testing

Verify certificate and current scope in the FDA registry

Pesticides · A-0434-037/13

Approved Scope

Specific analytes
Pesticides, multi-residue, see scope certificate for list
Matrices
Fresh and processed foods
Method / technology
PR-5-14 Determination of Pesticide Residues in Fresh and Processed Foods by Mass Gas Chromatography (based on AOAC 2007.01) · LC-MS
Effective date / source checked
2023-12-07 / 2026-10-16

Pesticide testing

Verify certificate and current scope in the FDA registry

Capsaicins · A-0434-037/13

Approved Scope

Specific analytes
Capsaicin, dihydrocapsaicin, norhydrocapsaicin
Matrices
Peppers
Method / technology
PR-5-82 Determination of Capsaicin, Dihydrocapsaicin, Norhydrocapsaicin (based on NOM-189-SCFI-2017, Havan Chile from the Yucatan Penisula (Capsicum Chinense Jacq.) - Specifications and test methods) · -
Effective date / source checked
2023-12-07 / 2026-10-16

No directory test category assigned.

Verify certificate and current scope in the FDA registry

Mycotoxins · A-0434-037/13

Approved Scope

Specific analytes
Aflatoxins (B1, B2, G1, and G2)
Matrices
cereals, seeds, vegetables and nuts
Method / technology
PR-5-103 Determination of aflatoxins B1, B2, G1 and G2 in cereals, seeds, vegetables and nuts (based on QuPPe-PO method by LC-MS/MS) · LC-MS/MS
Effective date / source checked
2023-12-07 / 2026-10-16

No directory test category assigned.

Verify certificate and current scope in the FDA registry

Toxic Elements · A-0434-037/13

Approved Scope

Specific analytes
Beryllium, iron, cadmium, arsenic, cobalt, chromium, lead, copper, zinc, antimony, selenium, tin, mercury, sodium, aluminum, barium, calcium, magnesium, manganese, nickel, silver, potassium, thallium, vanadium
Matrices
Food, drinking water and purified water
Method / technology
PR-5-30 Determination of Be, Fe, Cd, As, Co, Cr, Pb, Cu, Zn, Sb, Se, Sn, Hg, Na, Al, Ba, Ca, Mg, Mn, Ni, Ag, K, Tl and V in food, drinking water and purified water by atomic absorption spectrophotometry (Internal method derived from EAM 4.7) · Atomic Absorption (AA)
Effective date / source checked
2023-12-07 / 2026-10-16

Heavy metal testing

Verify certificate and current scope in the FDA registry

Sampling · A-0434-037/13

Approved Scope

Specific analytes
Sampling for microbiological analysis
Matrices
water, surface and food samples
Method / technology
PR-5-04 Collection, handling, transport and handling or water, surface and food samples for microbiological analysis · -
Effective date / source checked
2023-12-07 / 2026-10-16

Microbial and microbiological testing

Verify certificate and current scope in the FDA registry